Global Suppliers 50Hz/ 60Hz Cooling/ Heating Full DC Inverter Vrv Air Conditioner Vrf Villa Central Air Conditioning System
HomeHome > Products > Cooling System > Global Suppliers 50Hz/ 60Hz Cooling/ Heating Full DC Inverter Vrv Air Conditioner Vrf Villa Central Air Conditioning System
Global Suppliers 50Hz/ 60Hz Cooling/ Heating Full DC Inverter Vrv Air Conditioner Vrf Villa Central Air Conditioning System

Global Suppliers 50Hz/ 60Hz Cooling/ Heating Full DC Inverter Vrv Air Conditioner Vrf Villa Central Air Conditioning System

Overview ZERO VRF is a powerful system for your next HVAC project if you are looking for cost effective solutions. We of
Overview
Basic Info.
Cooling/Heating Cooling/Heating
Power Source Electrical
Power Type AC
Condition New
Heating Capacity 9kw-69kw
Cooling Capacity 8kw-61.5kw
Max.Esp 85
Power Supply 208-230V, 220-240V, 380-415V
Operating Temp. Range(Cooling/Heating) -5-55/-20-30
Comperssors DC Inverter
Refrigerant R410A
Outdoor Unit Aiflrow Rate dB(a) 45-63
Cop 3.56-5.5
Eer 3.32-4.72
Transport Package Pallet, PE Bag, Carton, Corner Protector
Trademark ZERO
Origin China
Production Capacity 30000 Set/Month
Product Description

Global Suppliers 50Hz/ 60Hz Cooling/ Heating Full DC Inverter Vrv Air Conditioner Vrf Villa Central Air Conditioning System

ZERO VRF is a powerful system for your next HVAC project if you are looking for cost effective solutions.
We offer one stop solution includes VRF drawing design, model selection, instalation material calculation, start upguidance etc, equipments, installation material and other parts will be loaded all together in the same containersdirectly ship to your job site, we make your VRF projects never been so easy.

WHY CHOOSE US

1.Experience
More than 15 years of overseas HVAC project experience,with deep understanding of global markets.
2.Professional design
Our professional design team are ready to provide you a AC plan drawing based on your architecture blueprint, we will advise themost suitable solution.
3.Professional selection
We can select the most suitable model for your project according to the drawings. 4.One-stop solution
The necessary installation material and other parts can be collected and loaded them all together directly ship to your job site,which is truly one-stop solution.
5.Technical support
Professional technical support, worry-free after sales.

Global Suppliers 50Hz/ 60Hz Cooling/ Heating Full DC Inverter Vrv Air Conditioner Vrf Villa Central Air Conditioning System

1.Project Drawing, building layout, equipment BOQ.
2.Project name: building name or building type, such as xxx office project, residential house project etc.
3.Expected shipping date of this project.
4.Project type: tender or self-owned.

Products Line

Global Suppliers 50Hz/ 60Hz Cooling/ Heating Full DC Inverter Vrv Air Conditioner Vrf Villa Central Air Conditioning System

8/10/12Hp 14/16HP 18/20HP 22HP 24HP 26/28/30/32HP13 BASIC MODULES (380V-3Ph-50/60Hz)
HP810121416182022
Dimension (mm)990*1740*8451340*1740*845
Fan quantity11111222
Compressor quantity11111222
HP2426283032
Dimension (mm)1990*1740*845
Fan quantity22222
Compressor quantity22222

Global Suppliers 50Hz/ 60Hz Cooling/ Heating Full DC Inverter Vrv Air Conditioner Vrf Villa Central Air Conditioning System

Specification

TypeMini VRFLarge VRF
CapacityHP3HP-12HP8HP-22HP
Power supplyV/Ph/Hz220-240V/1PH/50Hz208-230V/1PH/60Hz380-415V/3PH/50Hz & 60Hz208-230V/3PH/60Hz380-415V/3PH/50Hz & 60Hz
CoolingCapacitykW8KW~33.5KW25.2KW-61.5KW
kBtu/h27.3-60kBtu/h86-209.8kBtu/h
Power inputkW5.78-14.4KW17-27.65KW
EERkW/kW3.32-3.693.02-4.72
HeatingCapacitykW9KW-37.5KW27.4KW-69KW
kBtu/h92-191kBtu/h27.4KW-69KW
Power inputkW5.41-14KW15.8-26.08KW
COPkW/kW3.56-4.274.11-5.5
ComperssorsType-DC inverter
Fan motorsType-DC inverter
Max.ESPPa8585
RefrigerantTypeR410A
Aiflrow ratem³/hm³/h3300-800015000-17000
dB(A)dB(A)45-6058-63
Ambient tempCoolingºC-5-50ºC-5-55ºC
HeatingºC-20-30ºC-30-30ºC

Our Advantages

LONG PIPE & HEIGHT DIFFERENCE
1.The total pipe length: 1000 m.2.The longest pipe length: 200 /240m.3.Height deference:Outdoor unit. Above<90m<90m.4.Outdoor unit below<110m.5.Height difference between indoor units: 30m.6.Length from first indoor distributor to last indoor unit 90 m.7.Communication wire length can be upto 1000m.

CONTROLLERS AND SOFTWARESIMPLIFY CENTRALIZED CONTROLLEREasy to install.Controller connects to outdoor units only.
1 Controller can control max. 100 indoor units.
Operation mode restriction.
Error or protection code display
Can control single unit or all units together
INDOOR UNITS QUANTITY
Max. 100 Indoor units can be connected in ONE system.

WIRELESS REMOTE CONTROLLERS
Indoor unit address inquiry.
Indoor unit address setting.
Temperature setting.
Operation mode setting.
Fan speed setting.
Timer function.SERVICE WINDOW ON FRONT COVER
Thanks to the service window, checking outdoorunit's status and setting is now easy, no need toremove the front cover.

WIDE OUTDOOR OPERATION RANGE(380V)Max.cooling operating temperature is up to 55°C.Low ambient temperature of cooling mode can be downto-10ºC.

Global Suppliers 50Hz/ 60Hz Cooling/ Heating Full DC Inverter Vrv Air Conditioner Vrf Villa Central Air Conditioning System